XGS-PON ONU Stick SFP+ SC/UPC MAC I-Temp 9.95T/9.95R 1270T/1577R 20km

XGS-PON ONU Stick SFP+ SC/UPC MAC I-Temp

9.95T/9.95R 1270T/1577R 20km

Varenr:XGSONU-STICK-C-I
2 397,-Eks. mva
1 på lager

Logg inn for å se dine nettopriser
Ikke kunde? Registrer deg som bedriftskunde

Teknisk infoDatablad
Teknisk info

XGSONU-STICK-C-I – XGS-PON ONU SFP+ Stick with Integrated MAC, 10G, 1270/1577nm, 20km, SC/UPC


The GLOBALfiber XGSONU-STICK-C-I is an industrial-temperature XGS-PON ONU SFP+ Stick with integrated MAC, designed for 10-Gigabit-capable Passive Optical Networks.The module provides symmetric 9.953 Gb/s XGS-PON transmission over a single strand of single-mode fiber, using 1270 nm for upstream transmission and 1577 nm for downstream reception. With a reach of up to 20 km, an SC/UPC optical interface, integrated MAC functionality and support for OMCI, VLAN, AES-128 encryption and digital diagnostics, it is well suited for compact XGS-PON ONU applications.

Main Features
XGS-PON ONU SFP+ Stick
Integrated MAC
Hot-pluggable SFP+ form factor
Symmetric 9.953 Gb/s XGS-PON operation
10 Gb/s Ethernet upstream and downstream
Single-fiber bidirectional transmission
TX wavelength: 1270 nm
RX wavelength: 1577 nm
DML DFB transmitter
APD receiver
Maximum transmission distance: 20 km
Single-mode fiber, 9/125 µm
SC/UPC optical connector
Industrial operating temperature: -40°C to +85°C
Digital Diagnostics Monitoring
AES-128 encryption
Forward Error Correction, FEC
Automatic serial number and password activation
Remote debugging
Flexible XGEM port and T-CONT mapping
Maximum 8 T-CONT and GEMPORT
Low EMI design
ESD protection
RoHS-10 compliant

XGS-PON Optical Interface
The XGSONU-STICK-C-I uses wavelength division multiplexing to transmit and receive XGS-PON traffic over a single optical fiber.
Upstream wavelength: 1270 nm
Upstream wavelength range: 1260–1280 nm
Downstream wavelength: 1577 nm
Downstream wavelength range: 1575–1580 nm
PON TX rate: 9.953 Gb/s
PON RX rate: 9.953 Gb/s
Maximum reach: 20 km
Fiber type: Singlemode 9/125 µm
Optical connector: SC/UPC
Transmitter Specifications
Laser type: DML DFB
Average launch power: +4 to +9 dBm
Typical wavelength: 1270 nm
Wavelength range: 1260 to 1280 nm
Extinction ratio: =6 dB
Spectral width at -20 dB: =1 nm
SMSR: =30 dB
Burst-on time: =50 ns
Burst-off time: =50 ns
TDP over 20 km SMF: =1.5 dB
TX reflected-power tolerance: -15 dB minimum
Eye diagram compliance: ITU-T G.9807
Test pattern: PRBS 2³¹-1 at 9.953 Gb/s
Receiver Specifications
Receiver type: APD
Typical wavelength: 1577 nm
Wavelength range: 1575 to 1580 nm
Receiver sensitivity: -28 dBm maximum
Receiver overload: -8 dBm minimum
Receiver reflectance: -12 dB maximum
LOS Assert: -45 dBm minimum
LOS De-assert: -29 dBm maximum
LOS hysteresis: 0.5 to 5 dB
BER test condition: =1 × 10?³ at 9.953 Gb/s

Ethernet and MAC Features
The integrated MAC functionality makes the module suitable for compact ONU implementations where XGS-PON termination and Ethernet functionality are required in the SFP+ module.
Supported functions include:
IEEE 802.1Q VLAN virtual switching
Q-in-Q
VLAN translation
VLAN tagging
VLAN transparent mode
Class of Service based on VLAN ID
IEEE 802.1p CoS
MAC filtering
Loop detection

OMCI Management
The XGS-PON ONU Stick supports OMCI management functions including:
MIB Create
MIB Delete
MIB Set
MIB Get
MIB GetNext
Alarm reporting
Performance monitoring
Remote software download
Remote activation
Remote reboot

Digital Diagnostics Monitoring
Integrated digital diagnostics provide real-time monitoring of key operating parameters.
Temperature monitoring: -40°C to +85°C
Temperature accuracy: ±3°C
Supply voltage monitoring: 3.0 to 3.6 V
Supply voltage accuracy: ±3%
Bias current monitoring: 0 to 90 mA
Bias current accuracy: ±10%
TX optical power monitoring: +2 to +11 dBm
RX optical power monitoring: -30 to -7 dBm
Optical power accuracy: ±3 dB
Internal calibration

Electrical Specifications
Nominal supply voltage: 3.3 V
Operating voltage: 3.15 to 3.45 V
Maximum current consumption: 970 mA
Maximum power consumption: 3.2 W
TX impedance: 100 O typical
TX differential input swing: 200–1600 mV
RX differential output swing: 300–850 mV
AC-coupled interface
Environmental Specifications
Operating temperature: -40°C to +85°C
Storage temperature: -40°C to +85°C
Relative humidity: 5–95%
Industrial temperature version
Maximum power consumption: 3.2 W
Standards and Compliance
XGS-PON
ITU-T G.9807.1
ITU-T G.988
SFP+ MSA
SFF-8431
SFF-8472
RoHS-10
FCC 47 CFR Part 15 Class B
FDA 21 CFR 1040.10
FDA 21 CFR 1040.11

Applications
XGS-PON access networks
XGS-PON ONU applications
Fiber-to-the-Home, FTTH
Fiber-to-the-Business, FTTB
10G passive optical networks
SFP+ based XGS-PON ONU equipment
Compact integrated MAC ONU solutions

Datablad